Admins:MegaCli команды: различия между версиями

Материал из Справочная система
Перейти к навигацииПерейти к поиску
 
Строка 149: Строка 149:
*load controller defauts
*load controller defauts
::MegaCli -adpfacdefset -aALL
::MegaCli -adpfacdefset -aALL
[[Category:Admins]]

Текущая версия на 14:53, 25 августа 2023

Команды MegaCli

MegaCli лежит в /opt/lsi/MegaCli/

  • flash bios
MegaCli -adpfwflash -f /scripts/firmware/lsi_imr_fw.rom -aALL
MegaCli -adpfwflash -f imr_fw.rom -NoVerChk -aAll
MegaCli -adpfacdefset -aALL # reset to factory default
  • controller info
MegaCli -AdpAllinfo -aALL
MegaCli -PDGetNum -a0 # nubmer of discs
MegaCli -PDInfo -PhysDrv [64:0] -aALL
MegaCli -PDMakeJBOD -PhysDrv[64:4]
  • clear controller config to defaults
MegaCli -CfgClr -aALL
  • delete all
MegaCli -CfgLdDel -LALL -aALL
  • create raid
MegaCli -CfgLdAdd -r5 [64:0, 64:1, 64:2, 64:3] -a0
MegaCli -CfgLdAdd -r0 [64:4,64:5,64:6,64:7] -a0
  • get free devices
MegaCli -PDList -a0 | grep -e '^Enclosure Device ID:' -e '^Slot Number:'
  • get raid info
MegaCli -LDInfo -Lall -aALL
MegaCli -PDMakeGood -PhysDrv[64:4] -force -aALL > /dev/null
MegaCli -PDMakeGood -PhysDrv[64:5] -force -aALL > /dev/null
MegaCli -PDMakeGood -PhysDrv[64:6] -force -aALL > /dev/null
MegaCli -PDMakeGood -PhysDrv[64:7] -force -aALL > /dev/null
MegaCli -PDMakeJBOD -PhysDrv[64:4,64:5,64:6,64:7] -a0
MegaCli -CfgLdAdd -r0 [64:4,64:5,64:6,64:7] -a0
MegaCli -AdpEventLog -GetEvents -f logfile -aALL # Dump all events from the adapters event log to a file named logfile
MegaCli -PDList -aAll # Dump information about all Phsyical Disks
MegaCli -LDInfo -LAll -aAll # Dump information about all Logical Disks on all adapters
MegaCli -LdPdInfo -aAll # Dump information of all logical and physical disks on all known adapters
MegaCli -AdpSetProp -EnableJBOD 1 -aALL
MegaCli -CfgDsply -aAll
  • adapter diagnostic
MegaCli -AdpDiag -a0
  • Controller information
MegaCli -AdpAllInfo -aALL
MegaCli -CfgDsply -aALL
MegaCli -AdpEventLog -GetEvents -f events.log -aALL && cat events.log
  • Enclosure information
MegaCli -EncInfo -aALL
  • Virtual drive information
MegaCli -LDInfo -Lall -aALL
  • Physical drive information
MegaCli -PDList -aALL
MegaCli -PDInfo -PhysDrv [E:S] -aALL
  • Battery backup information
MegaCli -AdpBbuCmd -aALL

Controller management

  • Silence active alarm
MegaCli -AdpSetProp AlarmSilence -aALL
  • Disable alarm
MegaCli -AdpSetProp AlarmDsbl -aALL
  • Enable alarm
MegaCli -AdpSetProp AlarmEnbl -aALL
  • Physical drive management
  • Set state to offline
MegaCli -PDOffline -PhysDrv [E:S] -aN
  • Set state to online
MegaCli -PDOnline -PhysDrv [E:S] -aN
  • Mark as missing
MegaCli -PDMarkMissing -PhysDrv [E:S] -aN
  • Prepare for removal
MegaCli -PdPrpRmv -PhysDrv [E:S] -aN
  • Replace missing drive
MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
  • Rebuild drive
MegaCli -PDRbld -Start -PhysDrv [E:S] -aN
MegaCli -PDRbld -Stop -PhysDrv [E:S] -aN
MegaCli -PDRbld -ShowProg -PhysDrv [E:S] -aN
  • Clear drive
MegaCli -PDClear -Start -PhysDrv [E:S] -aN
MegaCli -PDClear -Stop -PhysDrv [E:S] -aN
MegaCli -PDClear -ShowProg -PhysDrv [E:S] -aN
  • MegaCli -PDMakeGood -PhysDrv[E:S] -aN
This changes drive in state Unconfigured-Bad to Unconfigured-Good.
  • Set the drive offline, if it is not already offline due to an error
MegaCli -PDOffline -PhysDrv [E:S] -aN
  • Mark the drive as missing
MegaCli -PDMarkMissing -PhysDrv [E:S] -aN
  • Prepare drive for removal
MegaCli -PDPrpRmv -PhysDrv [E:S] -aN
  • If you’re using hot spares then the replaced drive should become your new hot spare drive:
MegaCli -PDHSP -Set -PhysDrv [E:S] -aN
  • In case you’re not working with hot spares, you must re-add the new drive to your RAID virtual drive and start the rebuilding
MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
MegaCli -PDRbld -Start -PhysDrv [E:S] -aN
MegaCli -CfgLdAdd -r0 [0:1, 0:1] -a0
MegaCli -LDInfo -Lall -aALL
  • View all controleler informations
MegaCli -AdpAllInfo -aAll
MegaCli -LDSetProp CachedBadBBU -LALL -aALL
  • Delete all devices
MegaCli -CfgLdDel -LALL -aALL
MegaCli -CfgLdAdd -r1 [252:0,252:1] -a0
MegaCli -CfgLdAdd -r10 [252:0,252:1,252:2,252:3] -a0
  • create RAID5
MegaCli -CfgLdAdd -r5 [64:0,64:1,64:2,64:3] -a0
  • create RAID10
MegaCli -CfgSpanAdd -r10 -Array0[64:0,64:1] -Array1[64:2,64:3] -a0
  • create RAID10
MegaCli -AdpSetProp -EnableJBOD 1
  • Enable disks cache
MegaCli -LDSetProp EnDskCache -LAll -aAll
  • Force flash
MegaCli -adpfwflash -f ./12.12.0-0111.rom -NoVerChk -a0
  • load controller defauts
MegaCli -adpfacdefset -aALL